Our Flexible Thermocouple Extension Cable Type B with ceramic yarn insulation is designed for precision and toughness in extreme heat. Built to connect Type B thermocouples (platinum-rhodium alloy) to your measurement systems, this cable delivers accurate temperature readings up to 260°C. The ceramic yarn insulation is flame-resistant and super durable, while the stranded conductors and stainless steel overbraid make it flexible enough to snake through tight spaces without breaking a sweat. Rated for 300V and available with optional aluminum Mylar shielding, it keeps signals clean even in noisy environments. It’s the go-to choice for high-temperature applications where reliability can’t be compromised.
The thermocouple extension cable market is heating up, driven by growth in industries like aerospace, metallurgy, and glass manufacturing. With industrial processes pushing higher temperatures, there’s a rising demand for cables that can handle extreme heat while staying flexible and safe. Ceramic yarn insulation is gaining traction for its superior thermal resistance compared to traditional materials like fiberglass or silicone. Plus, as automation and precision monitoring become standard, low-noise cables with shielding are critical. Our Type B cable aligns perfectly with these trends, meeting IEC 60584-3 and ANSI MC96.1 standards while offering unmatched flexibility and durability.

| Thermocouple Type | Compensating Wire Type | Usage | EMF Standard | Precision Grade | General Grade | |||
| Temperature /℃ | Value /μV | Tolerance μV | EMF Range μV | Tolerance μV | EMF Range μV | |||
| K | KX,KCA or KCB | G | -25 | -968 | ±40 | -924~-1012 | ±80 | -880~-1 056 |
| 100 | 4096 | 4052~4140 | 4 008~4 184 | |||||
| H | -25 | -968 | ±40 | -924~-1012 | ±88 | -880~-1 056 | ||
| 100 | 4096 | 4052~4140 | 4 008~4 184 | |||||
| 200 | 8138 | 8094~8182 | 8 050~8 226 | |||||
| J | JX | G | -25 | -1 239 | ±62 | -1177~-1301 | ±123 | -1 116~-1 362 |
| 100 | 5269 | 5207~5331 | 5 146~5 392 | |||||
| H | -25 | -1239 | ±62 | - 177~-1301 | ±123 | -1 116~-1 362 | ||
| 100 | 5269 | 5207~5331 | 5 146~5 392 | |||||
| 200 | 10779 | 10717~10841 | 10 656~10 902 | |||||
| E | EX | G | -25 | -1432 | ±81 | -1351~-1513 | ±138 | -1 294~-1 570 |
| 100 | 6 319 | 6238~ 6400 | 6 181~6 457 | |||||
| H | -25 | -1432 | ±81 | -1351~- 1513 | ±138 | -1 294~-1 570 | ||
| 100 | 6319 | 6238~6400 | 6 181~6 457 | |||||
| 200 | 13421 | 13340~13502 | 13 283~13 559 | |||||
| T | TX | G | -25 | -940 | ±30 | -910~-970 | ±60 | -1850 |
| 100 | 4279 | 4249~4309 | 4189~4339 | |||||
| H | -25 | -940 | ±48 | -892~-988 | ||||
| 100 | 4279 | 4231~4327 | ||||||
| 200 | 9288 | 9240~9336 | ||||||
| N | NX or NC | G | -25 | -646 | ±43 | -603~-689 | ±86 | -560~-732 |
| 100 | 2774 | 2731~2817 | 2 688~2 860 | |||||
| H | -25 | -646 | ±43 | -603~-690 | ±86 | -560~-732 | ||
| 100 | 2774 | 2731~2817 | 2 688~2 860 | |||||
| 200 | 5913 | 5870~5956 | 5 827~5 999 | |||||
| SorR | SC or RC | G | 100 | 646 | ±30 | 616~676 | ±60 | 586~706 |
| H | 100 | 646 | - | - | ±60 | 586~706 | ||
| 200 | 11441 | - | - | 1.381~1 501 | ||||
This cable thrives in high-heat, high-stakes environments. In aerospace, it’s used for temperature monitoring in jet engines and exhaust systems. Metallurgy relies on it for furnaces and smelting processes, where temperatures soar. Glass manufacturing plants use it to ensure precise control during molten glass production. Its flexibility makes it a favorite for complex routing in tight machinery or confined spaces, and the stainless steel overbraid protects against abrasion and mechanical stress. Whether it’s a blazing furnace or a precision-driven aerospace setup, this cable keeps your temperature data spot-on.
Comparison Parameters Table
Parameter | Our Flexible Type B Extension Cable | Competitor A | Competitor B |
|---|---|---|---|
Conductor Material | Platinum-Rhodium Alloy (Type B) | Platinum-Rhodium Alloy | Platinum-Rhodium Alloy |
Insulation | Ceramic Yarn | Fiberglass | Silicone |
Temperature Range | -50°C to +260°C | -40°C to +200°C | -30°C to +180°C |
Outer Protection | Stainless Steel Overbraid | No Overbraid | Fiberglass Braid |
Voltage Rating | 300V | 250V | 300V |
Flame Resistance | High (Ceramic Yarn) | Moderate (Fiberglass) | Low (Silicone) |
Shielding | Optional Aluminum Mylar with Drain Wire | None | Basic Foil Shield |
Flexibility | High (Stranded Conductors) | Moderate | Low |
Certifications | IEC 60584-3, ANSI MC96.1 | ANSI MC96.1 | IEC 60584-3 |
Applications | High-Temp, Flexible Routing | General High-Temp | Limited High-Temp |
Our Flexible Type B Thermocouple Extension Cable sets the bar high. The ceramic yarn insulation handles temperatures up to 260°C, outlasting competitors’ fiberglass or silicone options. The stainless steel overbraid adds rugged protection without sacrificing flexibility, unlike cables with no outer layer or weaker braids. We offer optional aluminum Mylar shielding with a drain wire for superior noise reduction, giving you cleaner signals than basic or unshielded alternatives. Our stranded conductors make installation a breeze, even in tricky setups. Certified to IEC 60584-3 and ANSI MC96.1, this cable delivers reliability and performance you can trust for your toughest applications.
Choose our cable for a flexible, high-temperature solution that keeps your operations running smoothly and accurately, no matter the heat.




About Us:
Our 12,000㎡ factory is equipped with complete capabilities for research, production, testing, and packaging. We strictly adhere to ISO 9001 standards in our production processes, with an annual output of 1,200 tons. This ensures that we meet both quantity and quality demands. Furthermore, all products undergo rigorous simulated environment testing including high temperature, high pressure, and corrosion tests before being dispatched, ensuring they meet customer specifications.
For all our clients, we offer timely and multilingual after-sales support and technical consulting, helping you resolve any issues swiftly and efficiently.

Client Visits
Building Stronger Partnerships

We support all kinds of testing:


FAQs:
What is the Flexible Thermocouple Extension Cable Type B used for?
Connects Type B thermocouples to instrumentation for precise temperature measurements in high-temperature environments.What materials are used in this cable?
Platinum-rhodium alloy conductors, ceramic yarn insulation, and a flexible stainless steel overbraid for added durability.What’s the temperature range for this cable?
Rated for continuous use from -50°C to +260°C, perfect for extreme conditions.Is the ceramic yarn insulation flame-resistant?
Yes, it offers excellent flame resistance and maintains performance in high-heat settings.What industries rely on this Type B extension cable?
Aerospace, metallurgy, glass manufacturing, and high-temperature processing industries.How flexible is this cable?
The stranded conductors and ceramic yarn insulation provide high flexibility for easy installation in tight spaces.Does it comply with industry standards?
Meets IEC 60584-3 and ANSI MC96.1 for accuracy and color coding.Can it handle electrical interference?
Yes, the twisted pair design and optional shielding reduce noise for reliable signal transmission.