Our Armored Type S Thermocouple Extension Wire with flame-retardant PVC is built for precision and durability. Designed to connect Type S thermocouples (platinum-rhodium alloy) to measurement systems, this cable ensures accurate temperature readings in demanding environments. The flame-retardant PVC insulation keeps things safe by limiting fire spread, while the galvanized steel wire armor adds rugged protection against physical damage. Rated for temperatures from -30°C to +105°C and up to 300V, it’s a go-to for industries needing reliable temperature monitoring. With twisted pair construction and aluminum Mylar shielding, it cuts down on electrical noise, delivering clean signals every time.
The thermocouple cable market is growing steadily, driven by demand in industries like petrochemicals, power generation, and aerospace. As safety regulations tighten, flame-retardant cables are becoming a must-have, especially in high-risk settings like oil refineries or steel plants. The push for halogen-free and low-smoke materials is also shaping trends, but flame-retardant PVC remains a cost-effective choice for applications up to 105°C. With industrial automation on the rise, the need for durable, noise-resistant cables is only getting bigger. Our cable fits right into this sweet spot, offering both performance and compliance with standards like IEC 60584-3 and ANSI MC96.1.

| Thermocouple Type | Compensating Wire Type | Usage | EMF Standard | Precision Grade | General Grade | |||
| Temperature /℃ | Value /μV | Tolerance μV | EMF Range μV | Tolerance μV | EMF Range μV | |||
| K | KX,KCA or KCB | G | -25 | -968 | ±40 | -924~-1012 | ±80 | -880~-1 056 |
| 100 | 4096 | 4052~4140 | 4 008~4 184 | |||||
| H | -25 | -968 | ±40 | -924~-1012 | ±88 | -880~-1 056 | ||
| 100 | 4096 | 4052~4140 | 4 008~4 184 | |||||
| 200 | 8138 | 8094~8182 | 8 050~8 226 | |||||
| J | JX | G | -25 | -1 239 | ±62 | -1177~-1301 | ±123 | -1 116~-1 362 |
| 100 | 5269 | 5207~5331 | 5 146~5 392 | |||||
| H | -25 | -1239 | ±62 | - 177~-1301 | ±123 | -1 116~-1 362 | ||
| 100 | 5269 | 5207~5331 | 5 146~5 392 | |||||
| 200 | 10779 | 10717~10841 | 10 656~10 902 | |||||
| E | EX | G | -25 | -1432 | ±81 | -1351~-1513 | ±138 | -1 294~-1 570 |
| 100 | 6 319 | 6238~ 6400 | 6 181~6 457 | |||||
| H | -25 | -1432 | ±81 | -1351~- 1513 | ±138 | -1 294~-1 570 | ||
| 100 | 6319 | 6238~6400 | 6 181~6 457 | |||||
| 200 | 13421 | 13340~13502 | 13 283~13 559 | |||||
| T | TX | G | -25 | -940 | ±30 | -910~-970 | ±60 | -1850 |
| 100 | 4279 | 4249~4309 | 4189~4339 | |||||
| H | -25 | -940 | ±48 | -892~-988 | ||||
| 100 | 4279 | 4231~4327 | ||||||
| 200 | 9288 | 9240~9336 | ||||||
| N | NX or NC | G | -25 | -646 | ±43 | -603~-689 | ±86 | -560~-732 |
| 100 | 2774 | 2731~2817 | 2 688~2 860 | |||||
| H | -25 | -646 | ±43 | -603~-690 | ±86 | -560~-732 | ||
| 100 | 2774 | 2731~2817 | 2 688~2 860 | |||||
| 200 | 5913 | 5870~5956 | 5 827~5 999 | |||||
| SorR | SC or RC | G | 100 | 646 | ±30 | 616~676 | ±60 | 586~706 |
| H | 100 | 646 | - | - | ±60 | 586~706 | ||
| 200 | 11441 | - | - | 1.381~1 501 | ||||
This cable shines in tough environments. It’s perfect for underground installations, thanks to its steel wire armor, which protects against mechanical stress. In petrochemical plants, it handles temperature monitoring for reactors and pipelines. Power generation facilities rely on it for turbine and boiler systems, where precision is critical. Steel manufacturing and aerospace applications also benefit from its ability to withstand harsh conditions while maintaining signal integrity. Whether it’s a noisy industrial floor or a hazardous location, this cable keeps your temperature data accurate and safe.
Comparison Parameters Table
Parameter | Our Armored Type S Extension Wire | Competitor A | Competitor B |
|---|---|---|---|
Conductor Material | Copper-Nickel Alloy (Type S) | Copper-Nickel Alloy | Copper-Nickel Alloy |
Insulation | Flame-Retardant PVC | Standard PVC | LSZH |
Temperature Range | -30°C to +105°C | -20°C to +90°C | -40°C to +100°C |
Armor Type | Galvanized Steel Wire | Steel Tape | Stainless Steel Braid |
Voltage Rating | 300V | 300V | 250V |
Flame Retardancy | IEC 60332-1 Compliant | Non-Compliant | IEC 60332-3 Compliant |
Shielding | Aluminum Mylar with Drain Wire | No Shielding | Collective Screen Only |
Max Pairs | Up to 50 Pairs | Up to 36 Pairs | Up to 24 Pairs |
Certifications | IEC 60584-3, ANSI MC96.1 | ANSI MC96.1 | IEC 60584-3 |
Applications | Underground, Industrial, Hazardous | General Industrial | Indoor Industrial |
Our Armored Type S Thermocouple Extension Wire stands out for its robust design and versatility. Unlike others, we use flame-retardant PVC that meets IEC 60332-1 standards, ensuring safety without breaking the bank. The galvanized steel wire armor offers superior mechanical protection compared to standard steel tape or braids, making it ideal for underground or high-traffic areas. Our cables support up to 50 pairs, giving you more flexibility for complex setups than competitors’ 24 or 36-pair limits. Plus, the aluminum Mylar shielding with a drain wire tackles electrical noise better than unshielded or minimally screened options. We’ve got you covered with certifications like IEC 60584-3 and ANSI MC96.1, so you know you’re getting quality that lasts.
Choose our cable for a reliable, safe, and high-performing solution that keeps your operations running smoothly, no matter the challenge.




About Us:
Our 12,000㎡ factory is equipped with complete capabilities for research, production, testing, and packaging. We strictly adhere to ISO 9001 standards in our production processes, with an annual output of 1,200 tons. This ensures that we meet both quantity and quality demands. Furthermore, all products undergo rigorous simulated environment testing including high temperature, high pressure, and corrosion tests before being dispatched, ensuring they meet customer specifications.
For all our clients, we offer timely and multilingual after-sales support and technical consulting, helping you resolve any issues swiftly and efficiently.

Client Visits
Building Stronger Partnerships

We support all kinds of testing:


FAQs:
What is the Armored Type S Thermocouple Extension Wire used for?
Connects Type S thermocouples to measurement devices, ensuring accurate temperature readings in high-temperature industrial settings.What materials are used in the Armored Type S Thermocouple Extension Wire?
Flame-retardant PVC insulation, copper-nickel alloy conductors, and galvanized steel wire armor for mechanical protection.What’s the temperature range for this cable?
Rated for -30°C to +105°C, ideal for harsh industrial environments.Is the cable flame-retardant?
Yes, it uses flame-retardant PVC to reduce fire spread and enhance safety.What industries use Armored Type S Thermocouple Extension Wire?
Petrochemical, power generation, steel manufacturing, and aerospace industries.How does the armor benefit the cable?
The steel wire armor provides superior mechanical protection against physical damage and harsh conditions.Does it meet any standards?
Complies with IEC 60584-3 and ANSI MC96.1 for color coding and performance.Can it handle electrical noise?
Yes, twisted pair design and aluminum Mylar shielding minimize crosstalk and electromagnetic interference.